Read the last error string recorded by the async logger worker. This helper gives the textual detail behind has_failed().

Interface

moonbit
pub fn[S] AsyncLogger::last_error(self : AsyncLogger[S]) -> String {}

input

  • self : AsyncLogger[S] - Async logger whose last worker error should be inspected.

output

  • String - Last recorded worker error message, or an empty string if no error was recorded.

Explanation

Detailed rules explaining key parameters and behaviors

  • A later run() clears the stored error string only after that run has actually started.
  • If the worker loop fails, the error text is captured from the raised exception.
  • An empty string normally means no failure has been recorded.
  • Once a failure string is recorded, it stays in place until a later run() invocation actually starts and clears it.
  • Failure-driven shutdown does not clear the stored error string by itself, so the same last_error() text can remain visible even after the logger is already closed.
  • This helper reports worker execution errors, not ordinary overflow or backpressure conditions.
  • That reset happens before the restarted worker resumes drain work.

How to Use

Here are some specific examples provided.

When Need Failure Detail In Diagnostics

When a compact error message should be surfaced to operators:

moonbit
if logger.has_failed() {
  println(logger.last_error())
}

In this example, the error string is only read when failure is present.

When Export Full Async State

When custom diagnostics want to include the last error field directly:

moonbit
let err = logger.last_error()

In this example, the helper provides the textual failure detail without building a full snapshot.

Error Case

e.g.:

  • If no runtime failure has occurred, the method returns an empty string.

  • An empty string does not prove the queue is empty or the worker is idle; it only means no failure string is currently recorded.

  • If callers need broader context than just the error text, they should use state().

  • close() or shutdown() do not clear a previously recorded error string by themselves; the reset happens only after a later run() has already started.

  • If the same error string is still present after shutdown, that does not by itself mean cleanup was skipped; the logger may already be is_closed=true while the remaining pending-versus-dropped outcome still reflects the active runtime's shutdown path.

Notes

  1. Read this helper together with has_failed() when interpreting worker health.

  2. The stored value is a diagnostic string, not a typed error object.

  3. Pair it with is_running() or pending_count() when you need to know whether failure left the logger with unfinished backlog, because the previous error string can coexist with remaining pending records until later cleanup or restart.

Published from the repository docs folder with VitePress.